ADAS Diagnostic Tools

Shop ADAS Tools

Professional ADAS diagnostic, calibration, and safety-system equipment. Browse the full catalog below or call 866-217-0063 for help choosing.

Talk to an ADAS specialist 866-217-0063
Shop by Brand Browse by Category

Need help choosing? Call 866-217-0063 or message our experts.

✓ Leading ADAS & diagnostic brands ✓ Financing available via Affirm ✓ Expert support, before & after the sale ✓ Ships nationwide

Our store carries professional ADAS calibration and diagnostic equipment from the industry's leading brands — Autel, Bosch, TEXA, Launch, TopDon, Jaltest, and Atlas. Whether you run a collision center, a mechanical repair shop, a dedicated calibration bay, or a fleet service operation, you'll find the systems and accessories needed to calibrate today's camera, radar, and sensor-based safety systems.

Browse complete calibration frames and packages, diagnostic scan tools, camera and radar targets, alignment and setup tools, and heavy-duty truck & fleet equipment. Every platform supports static and dynamic calibration to OEM standards, and each order is backed by U.S.-based expert support before and after the sale. Not sure which system fits your vehicle coverage and bay space? Shop by brand or category above, or call 866-217-0063 and an ADAS specialist will help you build the right setup.

TEXA Video camera calibration mat for CADILLAC

$243.00
In stock
Product Details
Brand: TEXA

TEXA Video Camera Calibration Mat for Cadillac — Part #3909338

This is the OEM-matched calibration target mat for Cadillac front-facing camera systems, used within the TEXA RCCS (Radar & Camera Calibration System) workflow. If your shop performs windshield replacements, front-end repairs, or removes and reinstalls camera modules on Cadillac vehicles, this mat is the required target panel for completing a proper static calibration with TEXA IDC5 software.

What This Mat Does

Front camera calibration on modern vehicles isn't a reset — it's a guided procedure where the camera's field of view is verified against a known reference target placed at a specific position in front of the vehicle. The TEXA calibration mat provides that reference. It's designed to work with the RCCS 2, RCCS 3, or RCCS 3 EVO frame structure and TEXA's self-centering laser alignment system, ensuring the mat is positioned at the correct distance, height, and angle before the IDC5 software runs the calibration routine.

Using a generic or incorrect target mat will cause the calibration to fail or, worse, complete with incorrect aim data — meaning the camera's lane departure, automatic emergency braking, or adaptive cruise control systems will not perform as designed. Cadillac uses specific target patterns tied to their OEM calibration procedures. This mat matches those requirements.

Who Needs This

  • Auto glass shops: Windshield replacement on Cadillac vehicles with front cameras requires post-installation calibration. This mat is the target used in that process.
  • Collision repair centers: Any front-end work that disturbs the camera mount, bracket, or surrounding structure requires recalibration. This is the correct target for that job.
  • General repair shops with TEXA RCCS equipment: If you already own an RCCS frame and run Cadillac vehicles, this mat extends your coverage to complete the camera calibration procedure correctly.

Part of the TEXA RCCS Ecosystem

The TEXA RCCS system consists of three components working together: the calibration frame (RCCS 2, RCCS 3, or RCCS 3 EVO), the TEXA Navigator diagnostic interface (NANO S or TXT), and the vehicle-specific calibration panels or mats like this one. The IDC5 software walks the technician through positioning, alignment verification via the laser system, and the calibration routine itself. This mat is the Cadillac-specific piece of that workflow.

For exact Cadillac model and year coverage, contact us — Cadillac's ADAS lineup spans multiple platforms and not every model year uses the same procedure or target.

What's Included

  • 1x TEXA video camera calibration mat, Cadillac-specific pattern (Part #3909338)

The RCCS frame, laser alignment system, Navigator interface, and IDC5 software license are sold separately.

When Does a Shop Need This vs. a Full RCCS Kit

If you already own a TEXA RCCS frame and are adding Cadillac to your calibration coverage, this mat is the add-on you need — no new frame required. If you're starting from scratch with no ADAS calibration equipment, you'll need the full RCCS system. Call us and we'll walk through which configuration fits your shop's volume and vehicle mix.

Why Buy From OEM Diagnostic Tools?

We've specialized in professional diagnostic and ADAS calibration equipment since 2016. When you call us, you reach someone who understands the TEXA ecosystem and can tell you exactly which mats, panels, and frame configurations your shop needs — without upselling you on equipment you won't use. We offer free shipping, free technical support at 866-217-0063, and full manufacturer warranty on everything we sell.

Call 866-217-0063 for quick answers and help!

Save this product for later
Share this product with your friends
TEXA Video camera calibration mat for CADILLAC